Single-control Water Level Protector
Main parameters of products
Rated current:4A/250VAC
Inductive current:1A/250CAC
Thermal current:5A/250VAC
Maximum operating force:0.25
Minimum release force:0.05
Contact point:14.7±0.4mm
Differential travel:0.35mm
Contact clearance:0.4mm
Total height:89mm
Length of handspike:71mm
Travel distance:14mm
Straight line distance between installation holes:48mm
Characteristics of product:
This product is mainly used to protect the liquid level. It can switch off the power when the water level in the vessel is higher than the standard water level to reach the protection purpose.
Strength of appliance
Apply 1500VAC voltage between the live part and shell with leaking current of 5mA for 1 minute, it has no breakdown.
Insulation resistance:
Insulation resistance between the live part and uncharged part ≥ 100MΩ
Work principle
There is a switch and terminal 1, 2, 3 above the single controller. Of it, terminal 1 and 3 are often closed and terminal 1 and 2 are often opened. When the water level in the vessel rises, the floater will float upward, so terminal 1 and 3 are opened and terminal 1and 2 are closed. When the water level drops under the standard water level, terminal 1and 3 are closed and terminal 1 and 2 are opened and the electrical appliance can work normally.