EPS three-phase (power/lighting)emergency power supply
General (EPS three-phase (power/lighting)emergency power supply) |
a.Application: supply emergency power for electrical appliances and equipments of 380V/220V, like fire equipment , primary load , important load , fire emergency lighting or other loads. b.Specification range: 2.2KW-800KW c.Detail specification: 2.2, 3.7, 5.5, 7.5, 11, 15, 18.5, 22, 30, 37, 45, 44, 75, 93, 110, 132, 160, 187, 200, 220, 250, 280, 315, 400, 500, 630, 800KW, etc. d.Installation: floor type (standard power distribution box) e.Standby time: 90~120min (standard setting), can be set with standby time according to design requirement.HBES series EPS is designed through cooperating with German experts, it adopts integrated modularization inverter manufactured by international famous manufacturer, uses the latest IGBT inversion technology , CPU control, digital circuit and high integration electronic element, it is the high - tech environmental protection type patent product that supplies the second or third power supply for primary load, extra important load, fire facility, fire emergency lighting and so on.
|
Main characteristics (EPS three-phase (power/lighting)emergency power supply) |
Adopt the latest IGBT inversion module and high reliability integrated circuit, PWM technology, design of Four in One , simple structure, can supply power for any inductive or capacitive loads, realize fire response, remote control or floor intelligent control, fire central control; its main parts or elements use those of international famous brand with high reliability; and its conductors and equipments have the advantages of flame retardant property or no burning. |
Main advantages (EPS three-phase (power/lighting)emergency power supply) |
Static state without noise, no smoke, no environment pollution, no risk of fire, automatic switching, realize on-duty without anybody, energy saving, no power consumption at non emergency power supply, stable performance, safety and reliability, long service life, low comprehensive cost and good ratio of performance and price compared with generator unit. |
Application (EPS three-phase (power/lighting)emergency power supply) |
Suitable for electrical appliances of AC 380V and 220V. |
Main technical parameters (EPS three-phase (power/lighting)emergency power supply) |
Model |
HBES-2.2~800KW |
Input |
Voltage |
380 ± 20% |
Phase no. |
Three-phase four-wire +PE |
Frequency |
50Hz ± 5% |
Output |
Capacity |
2.2KW-800KW |
Voltage |
380V AC three-phase four-wire +PE |
Ratio of voltage stabilization |
±5%( emergency power supply ) |
Waveform |
Sine wave degree of distortion shall be ≤ 3% |
Frequency |
50Hz ± 0.5% |
Overload capacity |
Run normally for120% loads |
Switching time |
≤5s ( From commercial power to emergency power supply) |
Battery |
Maintenance-free sealing battery |
Standby time |
Standard type: 90min (may be set according to design requirement) |
Protection |
Short circuit protection, over current protection, phase failure protection |
Display |
LED or LCD |
Efficiency |
Emergency power supply: above 90%; commercial power: approximate to 100%. |
Running environment |
Temp.: -24 ~40 Relative humidity:0~90% Altitude: 2,000m below |
Applicable load |
Especial for inductive loads and mixed loads with inductance and capacitance. |
Noise |
Commercial power: no noise; No commercial power: less than 55dB; For above HBES-75kW, the sound reaches less than 65dB. |
Size/weight |
See the table of size/weight |
The way of opening the door and incoming wire |
Single open of front door, double-open of back door, inlet and outlet wire from bottom (for standard type) | |
HBES series EPS battery equipping and size/weight table (EPS three-phase (power/lighting)emergency power supply) |
No. |
Model |
Output power (KW) |
Size of main machine (mm) D×W×H |
Size of battery cabinet (mm) D×W×H |
Battery cabinet (Pcs.) |
Weight (kg) |
1 |
HBES-2.2KW |
2.2
|
600×600×1800
|
----- |
Battery in the main frame |
180(Including battery) |
2 |
HBES-3.7KW |
3.7
|
600×600×2000 |
----- |
Battery in the main frame |
360(Including battery) |
3 |
HBES-5.5KW |
5.5
|
800×600×2200 |
----- |
Battery in the main frame |
720(Including battery) |
4 |
HBES-7.5KW |
7.5
|
800×600×2200 |
----- |
Battery in the main frame |
860(Including battery) |
5 |
HBES-11KW |
11
|
800×600×2200 |
----- |
Battery in the main frame |
1030(Including battery) |
6 |
HBES-15KW |
15
|
800×600×2200 |
800×600×2200 |
1Pcs. |
1350(Including battery) |
7 |
HBES-18.5KW |
18.5
|
800×600×2200 |
800×600×2200 |
1Pcs. |
1380(Including battery) |
8 |
HBES-22KW |
22
|
800×600×2200 |
800×600×2200 |
1Pcs. |
1860(Including battery) |
9 |
HBES-30KW |
30
|
800×600×2200 |
800×600×2200 |
1Pcs. |
1900(Including battery ) |
10 |
HBES-37KW |
37
|
800×600×2200 |
800×600×2200 |
2Pcs. |
2620(Including battery ) |
11 |
HBES-45KW |
45
|
800×600×2200 |
800×600×2200 |
2Pcs. |
3570(Including battery ) |
12 |
HBES-55KW |
55
|
800×600×2200 |
800×600×2200 |
2Pcs. |
3630(Including battery ) |
13 |
HBES-75KW |
75
|
800×600×2200 |
800×600×2200 |
3Pcs. |
5340(Including battery ) |
14 |
HBES-93KW |
93
|
800×600×2200 |
800×600×2200 |
4Pcs. |
7220(Including battery ) |
15 |
HBES-110KW |
110 |
800×600×2200 |
800×600×2200 |
4Pcs. |
7320(Including battery ) | | |

|
|